** Note: The following procedures reset the console to its factory defaults. This means all show and all configuration information are lost. Only use these procedures if you are comfortable with what you are doing, have all the show data backed up on a disk, and have no other options. That said, caveat emptier ** |
| |
ETC (Obsession Line, Expression Line, Express Line, Idea, Microvision) All ETC consoles follow the same reset procedure: Hold down [7][8][9] on the keypad and turn the console off, and then back on. Do not release [7][8][9] until the console has rebooted. On some consoles you may get an error message [ system software incompatible] , just cycle the power again and the message will go away the board will be reset to factory defaults. |
| |
STRAND Mantrix Hold down the assign button and turn the console off. While still holding the assign button down, remove the A/C cable from the console. Wait 30 seconds. Replace the A/C cable. Turn the console back on. Release the the assign button. LP90 Level one clear: Hold down the [CLEAR] button (the one on the alpha part of the keyboard, not the one on the numeric keypad) and turn the power off. Wait 30 seconds. Turn the power back on. Release [CLEAR]. Level two clear: Hold down the [CLEAR] button (the one on the alpha part of the keyboard, not the one on the numeric keypad) and turn the power off. Remove the A/C cord. Wait 30 seconds. Replace A/C cord. Turn the power back on. Release [CLEAR]. |
| |
|
| |
|
| |
|
| |
|
| |
| |
| |
| |
| |
| |
| |
| |
| |
|
|
|